| After-sales Service: | Provide a Full Set of After-Sales |
|---|---|
| Power Supply: | 220V\380 |
| Certification: | CE, TUV, ISO |
Suppliers with verified business licenses

1.Refrigeration System | |
1.1. Working Mode | Mechanical compression two - stage cascade refrigeration mode |
1.2. Refrigeration Compressor | Imported piston - type compressor |
1.3. Evaporator | Coiled - tube evaporator |
1.4. Condenser | Plate - type heat exchanger |
1.5. Throttle Device | Thermal expansion valve, capillary tube |
1.6. Control Mode of Refrigerating Machine | The PID of the control system automatically adjusts the operating condition of the refrigerating machine according to the test conditions Cooling water flow regulating device for condensing pressure regulating valve Evaporating pressure regulating valve (to prevent the evaporator from freezing) Compressor suction cooling circuit Capacity regulating circuit The stirring motor makes the temperature around the container more uniform, the temperature drops faster, saves time and reduces energy consumption. |
1.7. Refrigerant | R404a/R23 (Ozone Depletion Potential is 0) |
2. Electrical Control System | |
6.1 Controller Model | - |
Display | PLC Touch Screen (7 - inch) |
Operation Mode | Single - point Operation |
Setting Mode | Touch - type Input |
Setting Range | High - temperature Upper Limit: +120℃ Low - temperature Lower Limit: -80℃ |
Temperature Resolution | 0.1℃ |
Input | PT100 |
Control Mode | Anti - integral Windup PID, Fuzzy Algorithm |
3. Safety Protection Devices | |
3.1 Refrigeration System | Compressor Overpressure Compressor Overheating Compressor Overcurrent |
3.2 Others | Main Power Supply Phase Sequence and Phase - loss Protection Relay Leakage Circuit Breaker, Sample Power Control Terminal, External Alarm Output Terminal |
4. Other Configurations | |
4.1 Sample Power Control Terminal | Relay Contact Control, AC220V, within 2A (Contacts closed during normal operation; contacts open when the equipment stops or malfunctions) |
4.2 Main Power Supply Leakage Circuit Breaker | AC220V, 50Hz, Single - phase Two - wire with Protective Ground Wire |
5. Transportation | The test chamber is of an integral type and transported as a whole |
5.1 Dimensions | Maximum transportation dimensions (excluding packaging): Refer to "Overall Dimensions" |
5.2 Weight | Maximum transportation weight (excluding packaging): Refer to "Weight" |
6. Operating Conditions | Guaranteed by the user for the following conditions |
6.1 Installation Site | Flat ground, good ventilation No strong vibration around the equipment No strong electromagnetic field interference around the equipment No flammable, explosive, or corrosive substances and dust around the equipment Drainage floor drain available near the equipment Bearing capacity of the site ground: Not less than 800kg/m² Appropriate space for use and maintenance around the equipment |
6.2 Environmental Conditions | Temperature: 15℃ ~ 35℃ Relative Humidity: ≤85% Air Pressure: 86kPa ~ 106kPa |
6.3 Power Supply Conditions | Power Supply AC220V, Three - phase Four - wire with Protective Ground Wire Allowable voltage fluctuation range: AC (220±22) V Allowable frequency fluctuation range: (50±0.5) Hz Protective ground wire earthing resistance: Less than 4Ω; Power supply by TN - S or TT method The user is required to configure an air or power switch of corresponding capacity for the equipment at the installation site, and this switch must be independently used for this equipment Power Capacity:3kW Maximum Current:10A |